Home ProductsElectromagnetic Flow Meter

Oil Industry Electromagnetic Flow Measurement , Industrial Flow Meter

Oil Industry Electromagnetic Flow Measurement , Industrial Flow Meter

    • Oil Industry Electromagnetic Flow Measurement , Industrial Flow Meter
    • Oil Industry Electromagnetic Flow Measurement , Industrial Flow Meter
  • Oil Industry Electromagnetic Flow Measurement , Industrial Flow Meter

    Product Details:

    Place of Origin: China
    Brand Name: Metlan
    Certification: CE/CMC/ISO9001
    Model Number: MTF

    Payment & Shipping Terms:

    Minimum Order Quantity: 1pc
    Price: negotiation
    Packaging Details: in wooden box
    Delivery Time: 7 working days after received your payment
    Payment Terms: T/T or western Union,
    Supply Ability: 100pcs per month
    Contact Now
    Detailed Product Description
    Product Name: Explosion-proof Integrated Type MTF Electromagnetic Flow Meter For Oil Industry Colour: Blue, Orange, Grey,silver, White
    Flange: ANSI 150#, JIs 10K, DIN Accuracy: ±0.2% OR ±0.5%
    Repetition: <±0.1%,<±0.25% Output Signal: 4-20mA,pulse,RS485
    Liner: PTFE,PU,CR,PFA,F46,IR Electrode: 316L,Hastelloy,Ti,Ta

    Oil Industry Electromagnetic Flow Measurement , Industrial Flow Meter

     

     

     

    Introduction:


    MTF electromagnetic flow meter, composed of sensor and converter, works based
    on Faraday’s law of electromagnetic induction. It is used to measure electrical

    conductivity of liquid or solid. Generally, the conductivity should be over 5υS/cm

    (electrical conductivity of tap water, raw water is about (100~500υS/cm).

     

     

    Instrument characteristic

     

    1). No baffles and running part inside the measuring tube, therefore no additional flow

    loss and no jams happen. Especially for measuring the flow of solid-liquid object, for

    example, sewage, mud pulp and CWS (coal water slurry).

     

    2). Only liner and electrode have direct contact with the measuring medium, by

    choosing correct liner and electrode,,then the corrosion resistance and wear resistance

    can be satisfied. Therefore it can be used in kinds of strong acid and alkali in chemical

    solutions.

     

    3). Easy for installation, 5D for front straight pipe, 2D for back straight pipe(D means

    inner diameter of chosen instrument).

     

    4). High accuracy, it is up to ±0.2%,it is capable for testing


    5). It provides the function of zero correction of sensor and automatic zero adjustment.


    6). It has multi-language interface to satisfy all the users’ requirements.


    7). It has the function of self-adjustment and self-checking.


    8). It has lightning-protection and electricity-protection circuits. The effective,

    anti-interference circuits apply to all kinds of bad environment.

     


    Features:


    1). Explosion-proof design accords with the national explosion-proof technology

    requirements and has been approved by tests and can be used in various

    explosion-proof places.


    2). It is the first domestic company that has electromagnetic flow meter with HART

    communication function .

     


    3). It adopts the international leading excitation technology, which circuit is simple,

    stable, and reliable.


    4). It has the function of infrared remote control and button operation so as to make

    the operation more convenient.


    5). It provides the function of zero correction of sensor and automatic zero adjustment.


    6). It has multi-language interface to satisfy all the users’ requirements.


    7). It has the function of self-adjustment and self-checking.


    8). It has lightning-protection and electricity protection circuits. The effective,

    anti-interference circuits apply to all kinds of bad environment.

     

     

     

    Electromagnetic flow meter for measuring Heat (Energy)

     

    It is a kind of metering instrument for measuring the heat (energy) from

    heat-conducting fluid which belong to the heat exchange system.

     

    Through carrying high accuracy and stable Platinum resistance (PT1000)

    as measuring elements, to make the heat(energy)meter has a very excellent

     

     

     

    Selectrion of Ground Ring

     

    If the pipe connecting to the meter is insulated,the ground ring is needed, generally

    metallic or non-metallic grounding rings or grounding electrode (non-metallic) material is

    available to adapt to the corrosion of the measured material.

     

    If the measured medium is abrasive, ground ring with neck should be used to protect

    lining material of two sides and to prolong its life.

     

    In order to make the reliable operation of the instrument, and to improve measurement

    accuracy, free from outside interference of Send potential,the sensor should have separate

    ground wire, and the ground ring of both sides of the sensors should be fitted when the

    ground resistance, in the pipe connecting to the sensor or non-metallic pipe, is less than 10Ω.

     

     

     

     

     

     

    NOTES

    1 , Do not open during the transportation, when unpacking,

    please be careful not to damage the instrument. Large diameter

    flow meter please using hoisting rings.

     

               2 ,After unpacking the instrument, please protect the liner

    surfance, the liner surface can not be placed on the ground or other

    work site.

     

              3 ,After wiring, check the screws are tightened, to ensure the

              sealability of junction box.

     

                       4 ,If the instrument is not in use for a long time, please close both

              ends of the sensor, placed in ventilated and dry place, to ensure that moisture

              and water can not enter the inside of the,instrument, and check it regularly .

     

     

     

     

    Selection :

    MTF series magnetic flow meter selection table

    Type of instrument MTF  
    Installation form -S Flange-type sensor
    -D Clamping-type sensor
    -C Insertion-type sensor
    Pipe diameter 15 15mm
    20 20mm
    25 25mm
    .... ....
    2400 2400mm
    Electrode form -F Standard and fixed type
    Electrode material A Stainless steel 316L
    B Hb
    C Ta
    D Ti
    E Hc
    F Tungsten Carbide
    G other
    Lining material R Rubber
    P PTFE
    O Please mark out others
    Measuring pipe material B 304 Stainless steel (Standard)
    C 316 Stainless steel
    Flange Material A 304 stainless steel
    B 316 Stainless steel
    C 20# Carbon steel
    Cover Material D Cover 304 stainless steel
    E Cover 316 Stainless steel
    F Cover Carbon steel paint (Epoxy metallic paint)
    Installation material flange 0 Without matching flange
    1 With matching flange
    Ground ring 0 Without ground ring
    1 With ground ring
    Rated voltage -10 1.0MPa
    -16 1.6MPa
    -40 4.0MPa
    Working temperature E ≦60℃
    H ≦180℃(devided type)
    Form of converter -I Integrated type
    -D Divided type
    Output signal and communication P Pulse
    A 4-20mA
    G 485 communication
    H Hart communication
    Q Others
    Power supply 0 220V AC
    1 24V DC
    2 Battery-powered
    Protection level 0 IP65
    1 IP67(devided type)
    2 IP68(devided type)
    Other features R Heat
    P With PT1000
    B Without PT1000
    Explosive proof level 0 Non-explosive proof
    EX EX

     

     

     

     

     

     

    Contact Details
    Nanjing Metlan Measurement & Control Instrument Co., Ltd

    Contact Person: Mandy Zhang

    Tel: +8613451802300

    Send your inquiry directly to us (0 / 3000)